Hitachi Cooling & Heating / SERIES OVERVIEW

Hitachi AVX Series

Air-cooled inverter screw chiller / heat pump

Brand
Hitachi Cooling & Heating
Series
AVX
Equipment category
Chillers
Hitachi AVX air-cooled inverter screw chiller / heat pump series reference image
Series reference image. Individual model configurations may differ.

Product overview

AVX uses R134a and inverter-driven semi-hermetic twin-screw compressors. Cooling-only RCUF and heat-pump RHUF ratings are kept in separate tables. Standard, all-year and heat-recovery selections require confirmation of the complete model and design conditions.

Key technical specifications

AVX: RCUF cooling-only references

Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.

AVX: RCUF cooling-only references. Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.
Model referenceCooling capacity(kW)Cooling input power(kW)Cooling COP(W/W)Main power supplyRefrigerantCompressor typeLength(mm)Width(mm)Height(mm)Net weight(kg)
RCUF150AVX5021543.26380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224565450
RCUF180AVX620193.83.199380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224565960
RCUF200AVX669209.13.199380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224566050
RCUF300AVX10043083.26380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245610900
RCUF330AVX1122347.83.226380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245611410
RCUF350AVX1171363.13.225380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245611500
RCUF380AVX1289402.93.199380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245612010
RCUF400AVX1338418.23.199380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245612100
RCUF450AVX15064623.26380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245616350
RCUF500AVX1673517.13.235380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245616950
RCUF550AVX1840572.23.216380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245617550
RCUF600AVX2007627.33.199380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245618150
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Published COP is kept per model.
  • Main supply is the brochure's 380 V / 3 phase / 50 Hz or 415 V / 3 phase / 50 Hz option, not a guarantee of both on one unit or 60 Hz availability.
  • Standard cooling envelope: leaving water 5–20 °C, outdoor dry bulb 5–50 °C. Heat-pump heating envelope: leaving water 35–60 °C, outdoor dry bulb −10–21 °C. All-year options have a separate envelope; extreme conditions can limit duty.
  • Brochure reference ratings are not a current stock or delivery guarantee. Confirm the complete configuration, nameplate, destination-market requirements and current selection before procurement.

AVX: RHUF heat-pump references

Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.

AVX: RHUF heat-pump references. Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.
Model referenceCooling capacity(kW)Cooling input power(kW)Cooling COP(W/W)Heating capacity(kW)Heating input power(kW)Heating COP(W/W)Main power supplyRefrigerantCompressor typeLength(mm)Width(mm)Height(mm)Net weight(kg)
RHUF150AVX5021543.26488148.83.28380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224566000
RHUF180AVX620193.83.199588186.53.153380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224566510
RHUF200AVX669209.13.199650200.93.235380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven6300205224566600
RHUF300AVX10043083.26976297.63.28380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245612000
RHUF330AVX1122347.83.2261076335.33.209380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245612510
RHUF350AVX1171363.13.2251138349.73.254380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245612600
RHUF380AVX1289402.93.1991238387.43.196380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245613110
RHUF400AVX1338418.23.1991300401.83.235380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven127002052245613200
RHUF450AVX15064623.261464446.33.28380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245618000
RHUF500AVX1673517.13.2351626498.53.262380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245618600
RHUF550AVX1840572.23.2161788550.63.247380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245619200
RHUF600AVX2007627.33.1991950602.73.235380 V or 415 V / 3 phase / 50 Hz (confirm selection)R134aSemi-hermetic twin-screw, inverter driven191002052245619800
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Published COP is kept per model.
  • Heating: leaving water 45 °C; water flow 0.172 m³/(h·kW); outdoor air 7 °C dry bulb / 6 °C wet bulb. These conditions differ from low-temperature G-series ratings.
  • Main supply is the brochure's 380 V / 3 phase / 50 Hz or 415 V / 3 phase / 50 Hz option, not a guarantee of both on one unit or 60 Hz availability.
  • Standard cooling envelope: leaving water 5–20 °C, outdoor dry bulb 5–50 °C. Heat-pump heating envelope: leaving water 35–60 °C, outdoor dry bulb −10–21 °C. All-year options have a separate envelope; extreme conditions can limit duty.
  • Brochure reference ratings are not a current stock or delivery guarantee. Confirm the complete configuration, nameplate, destination-market requirements and current selection before procurement.

Key configuration options

  • Standard cooling-only and heat-pump models are separate selections.
  • N all-year and heat-recovery configurations require model-specific confirmation; 50 Hz brochure ratings do not establish 60 Hz availability.

Applications

  • Central chilled-water systems
  • Project cooling / heating equipment selection subject to design conditions

Information for equipment selection

  • Complete model / configuration and equipment schedule
  • Required duty and design water / ambient conditions
  • Power supply, installation space and project location
  • Destination-market requirements and current availability confirmation

Application suitability requires a review of the project requirements and selected model.

Technical documents

No model-specific technical documents are available for download on this page. Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Prepare your equipment requirements

Product reference: Hitachi AVX Series

Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.

Request a Quote

Prepare your requirements on our inquiry page. Online submission is not connected yet.