YORK / SERIES OVERVIEW

YORK YCRU-K / YCRU-B Series

Kitchen / bathroom hydronic indoor-unit family

Brand
YORK
Series
YCRU-K / YCRU-B
Equipment category
Fan Coil Units

Availability Confirmed on Inquiry

YORK YCRU-K kitchen indoor unit with separate panel reference image
YCRU-K kitchen-unit illustration. YCRU-B bathroom-unit appearance and technical data await matching documentation.

Product overview

The reviewed YCRU nomenclature identifies K as the kitchen application and B as the bathroom application. Kitchen-unit K032E ratings are shown below. YCRU-B stock references are listed for availability inquiry only: no bathroom-unit capacity is inferred from the K table.

Inventory model references

The following supplied inventory references are available for inquiry. They are not a live stock guarantee or confirmation that every full code matches the brochure ratings below. Confirm the nameplate, complete configuration, condition and current availability.

  • YCRUK032ENLA
  • YCRUK032ENRA
  • YCRUB032EXLA
  • YCRUB032EXRA
Check Availability

Key technical specifications

YCRU-K032E: kitchen-unit reference only

The reviewed kitchen brochure contains this K032E reference at 0 Pa external static pressure. These values must not be applied to YCRU-B bathroom units or SP panel/accessory codes.

YCRU-K032E: kitchen-unit reference only. The reviewed kitchen brochure contains this K032E reference at 0 Pa external static pressure. These values must not be applied to YCRU-B bathroom units or SP panel/accessory codes.
Model referenceExternal static pressure(Pa)Rated airflow(m³/h)Total cooling capacity(kW)Heating capacity(kW)Heating (45 °C water)(kW)Voltage(V)Frequency(Hz)
YCRU-K032E05103.253.122050
  • Cooling: return air 27 °C dry bulb / 19.5 °C wet bulb; entering water 7 °C; water temperature rise 5 °C.
  • Heating: return air 21 °C dry bulb; entering water 60 °C or 45 °C respectively, at the cooling-rating water flow.
  • Airflow: standard air, dry coil, entering air 20 °C; tested at 220 V / 50 Hz, 0 Pa. The source explicitly specifies a 0 Pa rating.
  • The K nomenclature has 2-pipe selection, E = 0–10 V EC motor and optional N air-treatment kit. YCRU-B capacity / electrical configuration requires its own documentation.
  • Brochure ratings apply only to the listed model references and configuration. Confirm the complete model code, nameplate and current technical selection before procurement. They do not establish stock, export suitability or lead time.

Key configuration options

  • K and B are application variants, not interchangeable model ratings.
  • SP codes identify separate panel configurations in the reviewed nomenclature, not complete indoor units.
  • Confirm the body, panel, air-treatment kit and left / right arrangement before ordering.

Applications

  • Kitchen room cooling / heating with a hydronic system (K application)
  • Bathroom application variant (B); technical selection requires its own documentation

Information for equipment selection

  • Complete model code and required configuration
  • Cooling / heating duty and design water / air conditions
  • Electrical supply, quantity and project location
  • Installation arrangement and availability requirements

Application suitability requires a review of the project requirements and selected model.

Technical documents

No model-specific technical documents are available for download on this page. Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Prepare your equipment requirements

Product reference: YORK YCRU-K / YCRU-B Series

Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.

Request a Quote

Prepare your requirements on our inquiry page. Online submission is not connected yet.